Configuration, Configuration switches – Grass Valley Triton Plus Revision 5 User Manual
Page 10

10
Triton Plus - Ported RS-422 Data - User Manual
Configuration
Configuration
It is possible to use the router out-of-the-box. Changes to the factory set-
tings can be set with the DIP switches found in the back of the router.
As factory setting, the TPS-D32P is shipped with Dynamic ports. This
means every port can be controller or device depending on the connected
equipment.
Configuration Switches
You will find 2x10 DIP switches on the backplane of the router (see
).
Switches 1 - 4 set the router Level and the Physical Address for this unit. By
setting routers and Control Panels on same level, routers can be controlled
as one, i.e. Audio-follow-Video.
Panels in a NCB loop must be configured to the same level as the router(s).
The Levels/Physical Addresses can be set according to the following
pattern given in
. The default level is 1.
Table 2. Levels and Physical Addresses Switch Patterns
SW 1
SW 2
SW 3
SW 4
Level
Physical
Address
Off
Off
Off
Off
1
0
Off
Off
Off
On
2
1
Off
Off
On
Off
3
2
Off
Off
On
On
4
3
Off
On
Off
Off
5
4
Off
On
Off
On
6
5
Off
On
On
Off
7
6
Off
On
On
On
8
7
On
Off
Off
Off
9
8
On
Off
Off
On
10
9
On
Off
On
Off
11
10
On
Off
On
On
12
11
On
On
Off
Off
13
12
On
On
Off
On
14
13
On
On
On
Off
15
14
On
On
On
On
16
15