K2 raid for redundant k2 san, Cable k2 devices – Grass Valley K2 Storage SAN and Direct-Connect User Manual
Page 27

K2 RAID for redundant K2 SAN
These cabling instructions apply to the following:
•
K2 RAID (Condor with 10G controllers) on a redundant online or production K2 SAN.
Primar y
Expansion 1
Expansion 2
DP0
DP1
To
Expansion
3
To
Expansion
4
DP0
DP1
To
Expansion
3
To
Expansion
4
To K2 Media
Server A
To K2 Media
Server B
To control port
on GigE switch A
To control port
on GigE switch B
Contr oller 1
Contr oller 0
SAS cable connectors are keyed
to DP IN/OUT ports.
SAS cables
NOTE: Do not connect the controller MNT port. It should only be used
with a PC in a peer-to-peer connection for diagnostics purposes.
If you have more Expansion chassis than those illustrated, continue the indicated cabling pattern,
alternating connections for additional Expansion chassis between DP1 and DP0. Expansion chassis
1, 3, 5, 7, etc. (odd numbers) connect to DP1. Expansion chassis 2, 4, 6, 8, etc. (even numbers)
connect to DP0. For example, if you have four Expansion chassis (an even number), they are evenly
balanced, so you have two connected to DP1 and two connected to DP0. If you have five Expansion
chassis (an odd number), the “plus one” Expansion chassis is always connected to DP1, so you have
three connected to DP1 and two connected to DP0.
18 November 2010
K2 Storage Cabling Guide
27
Cable K2 devices