8960DEC—Instruction Manual
Configuration
Timing Web Page
The Timing web page shown in
appears when he optional
8900FSS Frame Sync submodule is installed on the 8960DEC module. If the
submodule is not installed, the web page will appear as shown in
.
The Timing web page provides lock source selection and fine phase adjust-
ments along with freeze controls for the input video. Refer to the Configu-
ration Summary in
for a summary of what video lines
are affected by each control, all parameters, step sizes, and default values.
Use the Timing display to set the following parameters:
•
Choose a Lock Source from
Reference
input or
Video In
input.
•
Adjust
H Phase
in nanoseconds and
V Phase
adjustment in lines.
•
Set
Freeze Recognition
to
Manual
or
Auto
.
Selecting
Auto
stores the last field
in the Frame Synchronizer to use if the input video is lost or corrupted.
•
Set the
Freeze Mode
to
Frame
or
Field
.
•
Set the
Freeze Field
to
Field 1
or
Field 2
.
•
Set the
Freeze Signal
to
Last Field
or
Black
. This will determine the freeze
signal when a freeze is activated in either
Auto
or
Manual
mode.
•
To perform a manual freeze, click the
Freeze
button at lower left.