Installation, Frame capacity, Module placement in the 8900 frame – Grass Valley 8912RDA User Manual
Page 8

8
8912RDA/RDA-D Instruction Manual
Installation
Installation of the 8912RDA module is a process of:
1.
Placing the module in the proper frame slot, and
2.
Cabling signal ports.
The 8912RDA module can be plugged in and removed from an 8900 Series
frame with power on. When power is applied to the module, LED indica-
tors reflect the initialization process (see
).
Frame Capacity
The 8912RDA module can be installed in all 8900 Series frames but with
varying maximum quantities determined by frame cooling capacity.
provides the power capacity, cooling capacity, and maximum
module count for each frame type.
Note
Module capacity figures assume no other modules are in the frame.
X = Not recommended without forced air cooling.
Module Placement in the 8900 Frame
There are ten slot locations in the frame to accommodate either analog or
digital modules. These are the left ten locations. Refer to
.
The two slots on the right are allocated for the power supplies. For addi-
tional information concerning the Power Supply module, refer to the 8900
Power Supply manual.
The third slot from the right is allocated for the Frame Monitor or Network
Interface Controller module. These modules provide health monitoring
and control options.
Table 1. Power, Cooling, and Module Capacity of 8900 Frames
Capacity Calculated
8900TX-A
Frame
8900TF-A
Frame
8900TFN-A
Frame
Power (W)
100
100
100
Recommended Module Cooling (W)
30
90
90
8912RDA Modules
10
10
10
8912RDA-D Modules
9
10
10