SCALEKLEEN INSTRUCTIONS FOR STEAMERS WITH EXISTING
EVERPURE FILTER
1. Remove and discard the existing Everpure filter cartridge from the
steamer.
2. For a small steamer (less than 10KW or 100,000 BTU’s), use
two 2.2 lb. (two kilogram) packages of ScaleKleen. For a large
steamer (greater than 10KW or 100,000 BTU’s), use four 2.2 lb.
(four kilogram) packages of ScaleKleen. For regularly scheduled
maintenance, reduce these quantities in half.
3. Remove the top plug assembly from the Everpure JT Cartridge.
NOTE: The JT Cartridge is designed to hold a maximum of one 2.2
lb. (one kilogram) package of ScaleKleen.
4. Cut one corner of the ScaleKleen package, and pour the contents
directly into the JT Cartridge. Once the ScaleKleen is in the
cartridge, carefully reinsert the top plug assembly.
NOTE: Ensure that the plug assembly is seated to the lugged outer
cap. If not, placement of the JT Cartridge into the head will be
hindered.
As an alternative, you can dissolve one 2.2 lb. (one kilogram) package
of ScaleKleen in warm water. Carefully pour the solution into the JT
Cartridge. Repeat this step until all of the solution has been used.
5. Insert the filled JT Cartridge into the head assembly, and turn the
shut-off valve to the fully opened position.
6. Flush the cartridge for a minimum of 1 gallon (a flow rate of 0.5
GPM would require 2 minutes) to transfer the ScaleKleen into the
boiler tank to be de-scaled.
7. Turn the steamer on. Once the steamer reaches operating
temperature, allow 30 minutes for the ScaleKleen to remove the
scale, then turn the steamer off.
8. Blowdown (flush) the boiler until the pH of the effluent is within one
pH unit of the incoming (influent) water.
9. Once the steamer has been flushed out, it can be placed back into
service.
10. After all de-scaling has been completed, remove the JT Cartridge
and install a new Everpure filter cartridge.
SCALEKLEEN INSTRUCTIONS FOR DRIP COFFEE MAKERS
1. Remove and discard the existing Everpure filter cartridge.
2. For coffee makers brewing one pot (1/2 gallon) per cycle, use
one 2.2 lb. (one kilogram) package of ScaleKleen. For regularly
scheduled maintenance, reduce these quantities in half.
3. Remove the top plug assembly from the Everpure JT Cartridge.
NOTE: The JT Cartridge is designed to hold a maximum of one 2.2
lb. (one kilogram) package of ScaleKleen.
4. Cut one corner of the ScaleKleen package, and pour the contents
directly into the JT Cartridge. Once the ScaleKleen is in the
cartridge, carefully reinsert the top plug assembly.
NOTE: Ensure that the plug assembly is seated to the lugged outer
cap. If not, placement of the JT Cartridge into the head will be
hindered.
As an alternative, you can dissolve one 2.2 lb. (one kilogram) package
of ScaleKleen in warm water. Carefully pour the solution into the JT
Cartridge. Repeat this step until all of the solution has been used.
5. Insert the filled JT Cartridge into the head assembly, and turn the
shut-off valve to the fully opened position.
6. Remove the filter basket and spray head, then dump the coffee
grounds from the machine. Place the spray head in the target
coffee pot.
7. Cycle the coffee maker once, vending one pot. Let it sit for 30
minutes. The spray head in the pot will also be cleaned.
8. After 30 minutes, cycle the coffee maker with 10 pots of fresh
water. This will flush the ScaleKleen from the boiler and water
lines. After the tenth pot, check the pH of the hot water. When
the pH of the hot water is within one pH unit of the incoming cold
water, the ScaleKleen is flushed out. Reassemble the spray head to
the coffee maker.
NOTE: If there is a hot water tap available, flush one pot through to
de-lime tap.
9. Once the coffee maker has been flushed out, it can be placed back
into service.
10. After all de-scaling has been completed, remove the JT Cartridge
and install a new Everpure filter cartridge.
CAUTION: In case of contact with eyes or skin, rinse thoroughly
with water. Avoid prolonged contact with stainless
steel surfaces. Contains salt which may cause surface
discoloration. Spots may be removed with a mild scouring
agent.
IF USING PH TEST KIT
1. Using one test strip, test and record the pH of the incoming water.
2. Using one test strip, test and record the pH of the product water
flowing from the de-scaled appliance.
3. When the pH of the outgoing product water is within one pH unit of
the incoming water, the ScaleKleen has been sufficiently flushed
out and the appliance can be placed back into service.
NOTE: Flushing the appliance with fresh water will raise the pH of
the product water.
For sales, replacement components, and service, contact your Everpure dealer or:
Everpure, LLC: 1040 Muirfield Drive • Hanover Park, Illinois 60133 • 800.323.7873
In Europe: Toekomstlaan 30 • B-2200 Herentals, Belguim
In Japan: Hashimoto MN Bldg. 7F • 3-25-1 Hashimoto Sagamihara-Shi • Kanagawa 229-1103, Japan
Printed in U.S.A.
EV3064-19A FE05