Model 7410 HD Tri-Level Sync Generator
7410-9
Run
Pwr
7410
Quad
TLS
Gen
1080/720p
59.94/50
1080/720p
59.94/50
1080/720p
59.94/50
1080/720p
59.94/50
525
625
10 Mhz
525
625
Remote
Local
E
D
E
S
I
G
N
S
N S E M B L E
Ref 1 Ref 2
Gen
1
2
3
4
Front Panel Controls and Indicators
Each front edge indicator and switch setting is shown in the diagram below:
Remote/Local switch:
Set to the mode you
will be using.
Pwr green LED:
Indicates the presence (ON) or
absence (OFF) of power (+5V).
Run green LED:
OFF:
A power fault or halted CPU
ON:
A halted CPU
FAST BLINK:
CPU Run error
SLOW BLINK:
System OK. (If SPI control is
active from the main frame
System Control Module, all
Run indicators will be syn-
chronized.).
Ref 525, 625 and 10 MHz
green LEDs:
One LED will light to indicate
which reference rate is currently
being detected.
OFF when rate is not detected.
Ref 525/625 green LEDs:
One LED will light to indicate
which reference rate is currently
being detected.
OFF when rate is not detected.
HD TLS
1080/720p switch:
Set to either 1080 (left) or 720p
(right) for the type of tri-level HD
sync output desired for Gen 1. Do
the same for Gen 2, Gen 3 and
Gen 4.
59.94/50 switch:
After selecting the above 1080 or
720p, then select either 59.94 or 50
Hz for Gen 1. Do the same for