• CAM ID – Assigns the camera ID from 1~255 for the comm. address.
• BAUD RATE – Selects the baud rate from 2400~115200.
• PROTOCOL – Selects the comm. Protocol from PELCO-D/P or VISCA.
9-1. TV SYSTEM
(default: US or EU)
: Selects HDTV standards for US(60HZ) or EU(50HZ). By this selection, 2nd
analog video output switches to NTSC or PAL accordingly.
9-3. COMM. SET UP
: COMM. SETUP defines the CAM ID, BAUD RATE and PROTOCOL.
Data length, stop bit and parity are fixed to 8bit, 1stop bit and no parity bit.
9-4. LANGUAGE
(default: ENG)
: 8 languages are available for ENGLISH, JAPANESE, GERMAN, FRENCH,
ITALIAN, SPANISH, POLISH and TURKISH.
9-5. FACTORY DEFAULT
(default: NO)
: RECALL ☟roads and saves the factory defaults.
9-2. RESOLUTION
(default: 1080P)
: Three resolutions,1080P/720P(SCALED)/720P(CROPPED) are available.
1080P outputs 1920x1080 video at the frame rate of 30P/25P.
720P(SCALED) Image is scaled down from 1080P and outputs 1280x720
video without loss of field of view at the frame rate of 30P/25P.
720P(CROPPED) image is cropped at the center area from the image sensor
and outputs 1280x720 video at the frame rate at 60P/50P but the image refresh
rate is 30P/25P. Cropped image has narrowed field of view
SYSTEM
TV SYSTEM
RESOLUTION
COMM. SETUP
LANGUAGE
FACTORY DEFAULT
RETUTN
EU(PAL)
1080P
ENG
NO
RET
9. SYSTEM
( Refer to ‘TIP’ page NO. 25)