Problem

Possible Cause

Possible Solution

Pump does
not start

Power is off

Turn power on

Power failure

Check power supply or
contact local power company

Voltage drop/
Overload

Check/Replace the GFI (Ground
Fault Interrupter)

Power cord is not
connected

Connect power cord

Pump stops after
starting

Pump is
overheating

Submerge pump/Raise water level/
Allow pump to cool

Power/Current
overload

Check length/size of power cable.
Check or replace GFI

Impeller is blocked

Remove debris from the
impeller chamber

Diminished
flow rate or
no water flow

Air lock

Submerse pump in a horizontal
position with the discharge facing up

Obstruction in pump
or piping

Clear obstruction

Low water level

Stop operation/Raise water level

Troubleshooting Guide

Always turn off power before inspecting the pump. Failure to observe this
precaution can result in a serious accident.

Before ordering repairs, carefully read through this instruction booklet. If
the problem persists, contact your dealer.