VENTING CHART

The appliance will not function without being connected to a proper venting system. This
appliance may only use direct vent system supplied by Archgard, or Simpson Dura-Vent
direct vent systems with Archgard SDA-U adapter.

Please strictly follow the venting instructions for optimum performance
from the appliance and to avoid sooting and/or service calls.

V
E
R
T
I
C
A
L

H
E
I
G
H
T

7.93 M

7.32 M

6.71 M

6.10 M

5.49 M

4.88 M

4.27 M

3.66 M

3.05 M

2.44 M

1.83 M

1.22 M

610 mm

Note: No Installations are per-
mitted outside of this range.

610
mm 1.22 1.83 2.44 3.05 3.66 Meters

A minimum of 3’ (914 mm) of vertical vent to center of elbow is required for a maximum horizontal
run of 3’ (914 mm).

Chart is for one 90° bend, with ¼” (7 mm) vertical raise minimum per foot of horizontal length.

For each additional 90° or two 45°, add one foot of vertical height.

Maximum three 90º bends, or equivalent.

Minimum 2 ft (610 mm) straight length between bends.

Feet

VENTING ABOVE ROOF OF THE HOUSE USING A VERTICAL TERMINATION

Use Simpson Dura-Vent listed direct vent system caps for all vertical vent termination

applications (through the roof).

No restrictors are to be used in

vertical or sidewall vent installations.