5 maintenance, 1 troubleshooting, 6 technical data – ARAG ORION User Manual
Page 8: 6technical data
8
5 MAINTENANCE
- After every spraying operation, flush the pipe with clean water.
- In case of malfunction, and at any rate at the end of every season, clean the flowmeter pipe with
a special detergent.
- Do not use metal or abrasive objects for cleaning the duct.
- Do not use solvents or petrol for cleaning the external parts of the device.
5.1 Troubleshooting
FAULT
CAUSE
REMEDY
The flowmeter does not read any
value
No power supply
• Check the flowmeter wiring.
The value read by the flowmeter is
not linear or stable
Presence of turbulence or air in the
circuit
• Check the circuit
.
Tab. 2
6
TECHNICAL DATA
Description
Orion
Power supply
11 ÷ 14,5 Vdc
Max. absorption
300 mA
Min. liquid conductivity
300 µScm
Working temperature
0 °C ÷ 60 °C
+32 °F ÷ +140 °F
Storage temperature
-20 °C ÷ 60 °C
-4 °F ÷ +140 °F
Dimensions (mm)
100x200x126 / 105x114x126 (depending on the type)
Weight
886 ÷ 1650 g (depending on the type)
Tab. 3
Flowrate
Internal
passages
Impulse/Liter
(Pulses/US Gal)
l/min.
US GPM
mm
pls/l
pls/US Gal
0,3 ÷ 6
0,08 ÷ 1,6
4
6000
22710
0,5 ÷ 10
0,13 ÷ 2,6
5
6000
22710
1 ÷ 20
0,3 ÷ 5
7
3000
11355
2,5 ÷ 50
0,6 ÷ 13
10
1200
4542
5 ÷ 100
1,3 ÷ 26
14
600
2271
10 ÷ 200
2,6 ÷ 53
18,5
300
1135
20 ÷ 400
5 ÷ 106
28
150
568
30 ÷ 600
8 ÷ 158
28
100
378
Tab. 4
CONTINUES