6.2
Cleaning the filters
6.2.1
Manual cleaning
Clean the filter regularly according to the instructions described below:
1 Protective gloves, goggles and
clothing must be worn.
2 Stop the machine and discon-
nect power to the unit.
3 Empty any remaining products
out of the system.
4 Unscrew the lock ring A by
turning it anticlockwise, slide the
lid
C and the cartridge B.
5 Wash the cartridge B and the
lid
C under running water.
6 Remove any trapped items
under running water.
Do not use compressed air
and/or sharp objects to clean
the cartridge.
Take care not to damage the mesh when cleaning the filter: should you notice any
damage to the mesh, replace the cartridge with a new one.
Refer to the ARAG spare parts catalogue for references for ordering spare parts.