2. hold the lower molded hose and Trim Grip steady, engage the Airsource lower as-
sembly by lining up the upper and lower connection points (Figure 6a) and carefully
turning counter-clockwise 1/4 turn (Figure 6b) until it snaps into place (Figure 6c).
Figure 7c
Figure 6b
Figure 6a
Figure 6c
Figure 7a
Figure 7b
Figure 7d
WARNING:
DO NOT disconnect the MP inflator hose while underwater
unless in an emergency situation. Disconnecting the MP inflator hose
while underwater will allow water and debris to enter the regulator caus-
ing premature wear and possible freeflow. If the MP inflator hose is
disconnected while underwater, the Airsource must be returned to an
Authorized Aqua Lung Dealer for service.
3. Re-attach the medium pressure (MP) inflator hose to the quick dissconnect fit-
ting of the Airsource by grasping the MP hose and pushing down onto the quick
disconnect fitting (Figure 7a-7b). Ensure that the medium pressure (MP) inflator
hose is securely attached. Slide the medium pressure (MP) inflator hose into
the upper (Figure 7c) and middle hose guides (Figure 7d).