Installation – Aqua Lung Airsource Quick Disconnect User Manual
Page 6

INSTALLATION
Aqua Lung recommends that you bring your Airsource, buoyancy compen-
sator and regulator together to your authorized dealer for the installation of
your Airsource. The retailer can also answer any questions you may have
pertaining to the information in this manual. If it is not possible to return to
your authorized dealer, you may install the Airsource onto your BC and attach
the MP inflator hose to your first stage by carefully following the steps in the
following procedure.
Attaching Airsource to BC
To install, unscrew original inflator assembly counterclockwise at the shoulder.
Place new Airsource assembly onto threaded portion, and screw clockwise until
tight. Make sure the gasket is in place and in good condition on the threaded
portion of the bc.
1. Remove the medium pressure (MP) inflator hose from the quick disconnect
fitting of the Airsource by grasping the collar of the MP inflator hose and slid-
ing it upwards (Figure 1). Detach the medium pressure (MP) inflator hose
from the hose guides at the middle (Figure 2) and top hose guides.
Figure 2
Attaching Mp hose to the first Stage
Figure 1
WARNING:
DO NOT connect the inflator hose to a high pressure (HP) port
(greater than 200 psi/14 bar). This may cause the hose to burst when pres-
surized, which can result in serious injury. If you are unsure which regulator
port is medium pressure (MP) or high pressure (HP), consult your regula-
tor's owner's manual or your dealer before attaching the hose.
6