INSTALLATION

Aqua Lung recommends that you bring your Airsource, buoyancy compen-

sator and regulator together to your authorized dealer for the installation of

your Airsource. The retailer can also answer any questions you may have

pertaining to the information in this manual. If it is not possible to return to

your authorized dealer, you may install the Airsource onto your BC and attach

the MP inflator hose to your first stage by carefully following the steps in the

following procedure.

Attaching Airsource to BC

To install, unscrew original inflator assembly counterclockwise at the shoulder.

Place new Airsource assembly onto threaded portion, and screw clockwise until

tight. Make sure the gasket is in place and in good condition on the threaded

portion of the bc.

1. Remove the medium pressure (MP) inflator hose from the quick disconnect

fitting of the Airsource by grasping the collar of the MP inflator hose and slid-

ing it upwards (Figure 1). Detach the medium pressure (MP) inflator hose

from the hose guides at the middle (Figure 2) and top hose guides.

Figure 2

Attaching Mp hose to the first Stage

Figure 1

WARNING:

DO NOT connect the inflator hose to a high pressure (HP) port

(greater than 200 psi/14 bar). This may cause the hose to burst when pres-

surized, which can result in serious injury. If you are unsure which regulator

port is medium pressure (MP) or high pressure (HP), consult your regula-

tor's owner's manual or your dealer before attaching the hose.