Setup, Prime and flush storage fluid – AIRLESSCO SP200 User Manual
Page 11

Setup
3A0994E
11
Setup
1.
Unscrew tip and guard assembly 
from gun.
2.
Uncoil hose and connect one 
end to gun. Use two 
wrenches to tighten securely
3.
Connect other 
end of hose to 
sprayer.
NOTE: If hose is already connected, make sure connec-
tions are tight.
4.
Turn OFF power switch.
5.
Turn Pressure Control Knob 
all the way left (counter-clock-
wise) to minimum pressure.
Prime and Flush Storage Fluid
NOTE: To spray lacquers with the SP300 and Mustang 
3100, you must purchase lacquer conversion kit 
256212, and follow priming procedure for oil-based 
materials. The SP200 and Mustang 2400 units are not 
intended for lacquers.
Before you use your sprayer for the first time or begin a 
new spraying project, you need to prime the sprayer and 
flush the storage fluid out of the sprayer.
Oil- or Water-based Materials
•
When spraying water-based materials, flush the 
system thoroughly with water.
•
When spraying oil-based materials, flush the sys-
tem thoroughly with mineral spirits or compatible, 
oil-based flushing solvent.
•
To spray water-based materials after spraying 
oil-based materials, flush the system thoroughly 
with water first. The water flowing out of prime tube 
should be clear and solvent-free before you begin 
spraying the water-based material. 
•
To spray oil-based materials after spraying 
water-based materials, flush the system thoroughly 
with mineral spirits or a compatible oil-based flush-
ing solvent first. The solvent flowing out of the prime 
tube should not contain any water.
•
When flushing with solvents, ground pail and gun. 
Read Grounding and Electric Requirements, page 
7.
•
To avoid fluid splashing back on your skin or into 
your eyes, always aim gun at inside wall of pail.
1.
Make sure the power switch is OFF 
and the sprayer is unplugged.
ti9714a
ti9681a
ti9674a
ti11456a
SP300 &
Mustang 3100
SP200 &
Mustang 2400
ti2810a
ti9344a
ti2810a