AEC 1-Pump 9-Station Controller User Manual
Page 19

1 –Pump 9-Station Controller
Chapter 3: Installation
18 of 38
Viewing System Status
The station and pump status screen (Shown below) can be viewed by pressing the F2 key on
the controller keypad.
Figure 3: Status Screen
This screen will show whether stations 1-9 and the pump (shown in the bottom right of the
screen- “P1”) are Ready or Offline. For a list of additional station and pump status names
and their description which may be displayed on this screen, see below.
Figure 4: Station Status Names & Descriptions
Name
Description
OFFLINE
Station is disabled or not installed.
READY
Normal idle condition.
DEMAND
Station is in demand, waiting to convey.
CONVEY
Convey to station is in progress.
UNLOAD
Convey is complete, station is now unloading.
NOCONV
Station has a no convey alarm.
PURGE
Station convey is complete – lines are being purged.
HIVAC
High vacuum alarm.
Figure 5: Pump Status Names & Descriptions
Name
Description
OFFLINE
Pump is disabled.
READY
Pump is idle and off.
IDLE
Pump is idle and running.
CONVEY
Pump is conveying or purging.
HIVAC
High vacuum alarm.
PMP FLT
Pump Verify alarm.
GEN FLT
User input alarm.
FLTR CAN
Filter can limit switch alarm.
Note: Pressing F1 while this screen is active will turn On or Off the conveying
system.
Press F6 to return to the Main Menu.