Westermo TD-22 User Manual
Page 40
41
6177-2203
Bit 3
Modem-to-modem flow control
0 =
Disabled (\G0) (Default.)
1 =
Enabled (\G1)
Bits 4-5
Reserved
Bit 7
Enable fallback to V.22 bis/V.22 (-Qn)
0 =
Disabled (-Q0)
1 =
Enabled (-Q1) (Default.)
S46 – V.42bis, Data Compression Control
136
Execute error correction protocol with no compression.
138
Execute error correction protocol with compression. (Default.)
S48 – V.42 Negotiation Action
0
Force LAPM connection.
7
Enable negotiation. (Default.)
128
Force action specified in S36.
Please also refer to S36.
S80 – Soft-Switch Functions (Stored directly in the E2 memory)
If switch SW2:1 is OFF, S80 will not be used
Bits 0
Selection of type of command
0 =
AT
1 =
V.25
Bit 2
Auto line quality and retain monitoring
0 =
No line monitoring or renegotiation (AT0)
1 =
Line monitoring or renegotiation (AT1)
Bit 3
Modem-to-modem flow control
0 =
Disabled (AT0)
1 =
Enabled (AT1)
Bit 4
MNP block or digit flow control
0 =
Disabled (AT0)
1 =
Enabled (AT1)
S82 – Break control for LAPM connections
3 – Break is sent immediately. Data in the buffer is stored
7 – Break is sent immediately. Data in the buffer is lost
128 – Break is buffered (Default.)
S86 – Call Failure Reason Code (Read only register, not stored with the AT&W command!)
This register is written with an indication of the error cause after a dialling error.
Default 0 {0..255}
S91 – PSTN Transmit Attenuation Level (Stored directly in the E2 memory)
Default 13 {0..15} dBm (Corresponding to 0 to -15 dBm transmit level.) Country dependant.
S92 – Fax Transmit Attenuation Level (Stored directly in the E2 memory)
Default 13 {0..15} dBm (Corresponding to 0 to -15 dBm transmit level.) Country dependant.
S95 – Extended Result Codes
Set by \V.
Default 0 {0..7}
S99 – Leased Line Transmission Level (Stored directly in the E2 memory)
Default 10 {0..15} dBm (Corresponding to 0 to -15 dBm transmit level.) Country dependant.