Westermo TD-22 User Manual
Page 35
36
6177-2203
S16 – General Bit Mapped Test Options Status (&T) (Read only register, not stored with &W)
Indicates the test in progress status.
Bit 0
Local analogue loopback
0 =
Disabled (Default.)
1 =
Enabled (&T1)
Bit 1
Not used
Bit 2
Local digital loopback
0 =
Disabled (Default.)
1 =
Enabled (&T3)
Bit 3
Remote digital loopback (RDL) status
0 =
Modem not in RDL (Default.)
1 =
RDL in progress
Bit 4
RDL requested (AT&T6)
0 =
RDL not requested (Default.)
1 =
RDL requested (&T6)
Bit 5
RDL with self test
0 =
Disabled (Default.)
1 =
Enabled (&T7)
Bit 6
Local analogue loopback (LAL) with self test
0 =
Disabled (Default.)
1 =
Enabled (&T8)
Bit 7
Radio sub carrier option (AT&E)
0 =
Disabled (&E0) (Default.)
1 =
Enabled (&E1)
S18 – Test Timer
Sets the length of time, in seconds, that the modem conducts a test (commanded by &Tn) before
returning to the command mode. If this register value is zero, the test will not automatically
terminate.
Default 0 {0-255} seconds
S19 – AutoSync Bit Mapped Options
Normally not editable by the user.
S20 – AutoSync HDLC Address or BSC Sync Character
Normally not editable by the user.
S21 – V.24/General Bit Mapped Options Status (Read only register)
Indicates the status of command options.
Bit 0
Set by &Jn command but ignored otherwise.
0 =
&J0 (Default.)
1 =
&J1
Bit 1
Reserved
Bit 2
CTS behaviour (&Rn)
0 =
CTS tracks RTS (&R0)
1 =
CTS always on (&R1) (Default.)
Bits 3-4
DTR behaviour (&Dn)
0 =
&D0 selected (Default.)
1 =
&D1 selected
2 =
&D2 selected
3 =
&D3 selected