6623-2211

Type tests and environmental conditions

Phenomena

Test

Description

Test levels

ESD

EN 61000-4-2

Enclosure contact

± 4 kV (crit A)

Enclosure air

± 8 kV (crit A)

RF field AM modulated

IEC 61000-4-3

Enclosure

10 V/m (crit A)

(80 – 2700 MHz)

Fast transient

EN 61000-4-4

Signal ports

± 1 kV (crit A)

Power ports

± 2 kV (crit A)

Surge

EN 61000-4-5

Ethernet ports

± 1 kV (direct) (crit A)

Power ports

± 0.5 kV (line to earth) (crit A)
± 0.5 kV (line to line) (crit A)

RF conducted

EN 61000-4-6

All ports

10 V/m, (crit A)

(0.15 – 80 MHz)

Radiated emission

EN 55022

Enclosure

Class B

Conducted emission

EN 55022

AC power ports

Class B

EN 55022

Ethernet ports

Class B

Temperature

Operating

–20 to +60ºC

(–30 to +70ºC restricted operation)

Storage & Transport

–40 to +85ºC

Humidity

Operating

0 to 90% relative humidity non

condensing.

Storage & Transport

0 to 90% relative humidity non

condensing.

Altitude

Operating

2000 m / 70 kPa

Service life

Operating

10 year

Dimension W x H x D

103 x 55 x 156 mm

Weight

0.43 kg

Degree of protection

IEC 529

Enclosure

IP 40

Cooling

Convection

Mounting

Horizontal on 35 mm DIN-rail