Connections md-54 – Westermo MD-54 User Manual
Page 4

15
6605-2001
Designation Description
PWR
Power supply OK
RD0
RD signal channel 0
TD0
TD signal channel 0
L1
RTS signal channel 0
L2
–
L3
CTS signal channel 3
L4
–
L5
RD signal channel 3
L6
TD signal channel 3
L7
RTS signal channel 3
L8
–
Connections MD-54
Direction
Connection
CCIT V.11
no.
Description
Receiver
1
A’ (R+)
Receiver
2
B’ (R–)
Transmitter
3
A (T+)
Transmitter
4
B (T–)
5
Shield
Connection channel 0, RS-422/485
LED’s description
Direction
Connection
CCITT V.24
Signal description
DCE
9-pos D-sub
Description
O
2
104
RD/Received Data
I
3
103
TD/Transmitted Data
–
5
102
SG/Signal Ground
I
7
105
RTS/Request To Send
O
8
106
CTS/Clear To Send
I = Input MD-54
O = Output MD-54
Connection channel 0, RS-232/V.24
Direction
Connection
CCITT V.24
Signal description
DCE
no.
Description
I
1
103
TD/Transmitted Data
O
2
104
RD/Received Data
I
3
105
RTS/Request To Send
O
4
106
CTS/Clear To Send
–
5
102
SG/Signal Ground
I = Input MD-54
O = Output MD-54
Connection channel 3, RS-232/V.24
Digital In, channel 1, 2 and 4 not used.
The definations R+/R–, T+/T– can be various between
different manufactures.