Mounting, Removal – Westermo Lynx-x05-S1-EX User Manual
Page 17

17
6643-22801
Mounting
This unit should be mounted on 35 mm DIN-rail, which is horizontally mounted inside an 
apparatus cabinet or similar. It is recommended that the DIN-rail is connected to ground. 
Snap on mounting, see figure.
Mounting Lynx with integrated DIN-clip:
Removal
Cooling
This unit uses convection cooling. 
To avoid obstructing the airflow 
around the unit, use the following 
spacing rules. Minimum spacing 25 mm 
(1.0 inch) above / below and 10 mm 
(0.4 inches) left / right the unit. 
Spacing is recommended for the use 
of unit in full operating temperature 
range and service life.
10mm
10mm
Removing Lynx with integrated DIN-clip: 
Press down the support at the back of the unit using a screwdriver. See figure.
                    This manual is related to the following products:                                    
                                                                        