Safety control drawing – Westermo Lynx-x05-S1-EX User Manual
Page 13

13
6643-22801
LED Indicators (for details see page 14)
Power connection (for details see page 9 and 13)
I/O connection
(for details see page 10 and 13)
RS-232
Position Signal Direction Description
Input/output values
No.1
DSR
Out
Data Set Ready
U = ±12 V max
I = ±60 mA max
Data rate:
50 bit/s – 115.2 kbit/s
No. 2
DCD
Out
Data Carrier Detect
No. 3
DTR
In
Data Terminal Ready
No. 4
SG
–
Signal Ground, not chassis
ground
No. 5
RD
Out
Receive Data
No. 6
TD
In
Transmit Data
No. 7
CTS
Out
Clear To Send
No. 8
RTS
In
Request To Send
Safety control drawing
Location of interface ports and LED’s
Ethernet connection TX (4 ports)
Position Signale Direction Description
Input/output values
No.1
TD+
In/Out Transmitted/Received data
Per port:
U = ± 1 V (4μV/s)
I = ± 20 mA
Data rate:
10/100 Mbit/s
No. 2
TD–
In/Out Transmitted/Received data
No. 3
RD+
In/Out Transmitted/Received data
No. 4
–
Not Connected
No. 5
–
Not Connected
No. 6
RD–
In/Out Transmitted/Received data
No. 7
–
Not Connected
No. 8
–
Not Connected
Shield
Connected to PE
Galvanically isolated via signal transformers and capacitively isolated to
GND/PE through a 2kV 1000pF capacitor.
See user manual for proven transient protection.
USB
Position Direction* / description
Output values
1
Out / VBUS
U
out
= 5 VDC max
I
out
= 500 mA max
2
In/out / D–
3
In/out / D+
4
GND
Shield
PE