27
6609-2222
Escape Delay
Define the delay time in seconds after the escape sequence been sent until the next
AT-command will be sent.
Allowed values,1 to 9999
If this value is set to zero, the unit will do nothing but wait!
Default: 2 (seconds)
Idle Time
If no data is being sent over the PPP link the ED-20 will close the connection.
Define the time in seconds.
Allowed values,0,1 to 9999
Default: 0 (function disabled)
Modem AT-Commands
Commands used in PSTN mode for controlling the behaviour of the attached
modem.
Note! Refer to the user guide or installation manual to the attached modem.
Modem Init
Command
Init string that will be sent to the modem.
Default: AT&F&D0S0=0&K3+MS=V34;&W
Answer
Expected answer from the modem on the sent command.
Allowed string length: 25 characters.
Default: OK
Timeout
Define the time in seconds between the sent command and the expected answer
before the command have failed.
Allowed values: 0 to 9999
Default: 3
Retries
Define the number of retries in case if a failed command.
Allowed values: 0 to 9999
Default: 1
Modem Hangup
Command
Hangup string that will be sent to the modem.
Allowed string length: 25 characters.
Default: ATH
Modem AT-Commands
Modem Init
Modem Hangup