Westermo ED-10 TCP User Manual
Page 12

12
6609-2211
CH2: RS-232 Connections (D-sub connector), DCE
CH1 and CH2 are not galvanic isolated.
Please use a RS-232 isolator (e.g. MD-52) if earth voltage differences are suspected. An isolator on
permanently connected CH2, is required to maintain the enhanced transient/surge protection of CH1.
5
4
3
2
1
9
8
7
6
Pin
Signal Name*
Number Description
V.24
RS-232C
Direction**
Description
1
DCD
109
CF
–
Data Carrier Detect, not connected
2
RD
104
BB
Out
Received Data
3
TD
103
BA
In
Transmitted Data
4
DTR
108.2
CD
–
Data Terminal Ready, not connected
5
SG
102
AB
In/out
Signal Ground
6
DSR
107
CC
–
Data Set Ready, not connected
7
RTS
105
CA
In
Request to Send, not used
8
CTS
106
CB
Out
Clear to Send, not used
9
RI
125
CE
–
Ring Indicator, not connected
* Functionality might differ from standard, see chapter 7.3
** Direction relative ED-10 TCP.
RS-232 cable must not exceed 15 m
Ethernet 10Base-T Connection (RJ-45 connector),
straight function MDI (no crossover)
Contact
Signal Name
Direction*
Description
1
TD+
Out
Transmitted Data
2
TD–
Out
Transmitted Data
3
RD+
In
Received Data
4
Not connected
5
Not connected
6
RD–
In
Received Data
7
Not connected
8
Not connected
* Direction relative ED-10 TCP.
CAT 5 cable is recommended.
Unshielded (UTP) or shielded (STP) connector might be used.