beautypg.com

Getting started – Westermo DR-250 User Manual

Page 15

background image

15

6622-2211

Getting started

IP Address

The default IP address of the DR-250 when delivered is 192.168.0.99.

IP address configuration

The IP address is configurable by the Web tool and/or by using a terminal program.
Below is an description of how to configure the IP address by using a terminal program.

1. If the address is known, connect to the unit from a Web browser with the address of

the DR-250. If the address is unknown, connect the serial RS-232 interface to a termi-
nal program with settings:
Data rate: 115.2 bit/s
Data bits: 8
Stop bits: 1
Parity: None
Flow control: None

2. Use any terminal-program to setup the IP-address, gateway and subnetmask.

Eth 0 ipaddr xxx.xxx.xxx.xxx (set up IP-address)
Eth 0 gateway yyy.yyy.yyy.yyy (set up Gateway)
Eth 0 mask zzz.zzz.zzz.zzz (set up subnetmask)
Eth 0 status (check settings)
Config 0 save (save configuration)

3. The unit is now ready for a complete configuration by the Web tool. Address DR-250

in a browser with the configured IP address. Note that the used computer have to be
on the same network as DR-250.

Username and Password for configuration

The DR-250 is username and password protected. These are used when connecting with
Web browser during configuration and with Telnet for diagnostics.

Default username: username
Default password: password

Restore Factory default settings

Note! This will clear your customized settings.

The factory default settings can be restored using the reset switch on the bottom of the
unit. Pressing (~15 sec) the switch gently with the tip of a pen or other suitable imple-
ment will generate a hardware reset.

Note! If the default address of the unit is valid on the connected network it is possible
to access the unit directly from a browser.

It is important to allow the DR-250 to complete the restore procedure. DO NOT press
the reset button again or power cycle the unit for at least 2 minutes.