Interface specifications – Westermo DDW-221 User Manual
Page 10

10
6642-22102
Interface specifications
Power
Rated voltage
20 to 48 VDC
Operating voltage
16 to 60 VDC
Rated current
300 mA @ 20 VDC
150 mA @ 48 VDC
Rated frequency
DC
Inrush current, I
2
t
3.1 A
2
s
Startup current*
400 mA
Polarity
Reverse polarity protected
Redundant power input
Yes
Isolation to
Ethernet, SHDSL
Connection
Detachable screw terminal
Connector size
0.2 – 2.5 mm
2
(AWG 24 – 12)
Shielded cable
Not required
* If external power supply is used it must meet specified inrush current.
SHDSL
Electrical specification
ITU-T G.991.2 Annex B
Data rate
192 kbit/s to 5696 kbit/s
Protocol
EFM according to IEEE 802.3-2004
Transmission range
According to ITU-T G.991.2 depending on the line quality
Protection
Overcurrent / overvoltage protection circuit and varistor
Isolation to
Power, Ethernet
Connection
Detachable screw terminal
Connector size
0.2 – 2.5 mm
2
(AWG 24 – 12)
Shielded cable
Not required
Number of ports
2
Ethernet TX
Electrical specification
IEEE std 802.3 2000 Edition
Data rate
10 Mbit/s, 100 Mbit/s, manual or auto
Duplex
Full or half
Transmission range
100 m / 328 ft
Isolation to
Power, SHDSL
Connection
RJ-45
Shielded cable
Not required, except when installed in Railway applications as
signalling and telecommunications apparatus and located close
to rails**
Number of ports
4 ports marked as 1, 2, 3, 4
** To minimise the risk of interference, a shielded cable is recommended when the cable is located inside 3 m
boundary to the rails and connected to this port.