Getting started – Westermo ED-2x0 User Manual
Page 8
![background image](https://www.manualsdir.com/files/809542/content/doc008.png)
8
6609-2281
Getting started
IP Address
When delivered, the default IP address of the ED-200 and ED-210 is 192.168.2.200.
Default gateway 192.168.2.200
If the default address of the unit is valid in the connected network it is possible to access
the unit directly from a web browser.
Change local IP address
The local address of ED-200/ED-210 can be configured using the IP Configuration tool,
then it is possible to browse into the unit for further configuration. The IP Configuration
program is available on the CD or for download from the WESTERMO web page:
http://www.westermo.com
, (choose Downloads/Software/Ethernet/ED-200, ED-210
Name: setup.exe
Install the software and start the application from a PC on the network connected to the
same network as the ED-200/ED-210. Make sure that the Default IP of the configuration
software (see figure below) is in the same subnet as your PC.
Note! If you are not sure about the subnet – consult your network administrator.
Note! IP Config version must be 9.8.4 or higher.
By clicking the “Scan for switches” button the IP Configuration tool will detect the switches/routers in
the network. The software will list all Westermo managed switches or routers connected to the net-
work. Information as in the figure 1 will appear for each detected unit connected to the same network
as your PC.
If you only want to change the IP address and the subnet mask, this can be done
within the IP config tool.
By clicking the listed ED-200/ED-210 that you wish be re-configured you will be
asked if you would like to access via web figure 2. Click the abort button,
enter the preferred IP address, Subnet mask and IP gateway address and click the
Set button to confirm the settings in the unit (see figure 3).
Figure 1
Figure 2
Help
About
Scan for switches
Close
Default IP:
Device list:
IP Adress
Subnet Mask
MAC Adress
SW Ver
Type
Status
192. 168. 2. 60
192.168.2.200 255.255.255.0 00-07-7C-80-4A-6C 9.74
ED-200
Mask: 255. 255. 255. 0
IP configuration
Access switch via web?
Cancel
OK
IP configuration
Note! If you are not
sure about the settings
– consult your network
administrator.