Connect surge protection and power, Attach the pole-mount cabinet – Wavetronix SmartSensor HD (101-0415) - Quick-reference Guide (Installer) User Manual
Page 3
7
Connect surge protection and power
1 Attach the mounting brackets to the back of the pole-mount box;
thread in the mounting straps.
2 Position the pole-mount box onto the pole and attach the box to
the pole using the mounting straps.
3 Run the sensor/homerun cables through the cable grips on the bot-
tom of the pole-mount box.
SmartSensor HD normally ships with one of two cable types. Newer installations will use the 8-conduc-
tor cable, but some installations may still use the 9-conductor cable. The wiring of these cables differs very
slightly. The image below shows the wiring of the 8-conduc-
tor cable; below that, the differences in wiring the 9-conduc-
tor cable are explained.
This covers the basics of how to wire the Click 200:
1 Disconnect the Click 200 from the DIN rail.
2 Disconnect the green screw terminals on the appropriate
side of the Click 200 and wire the sensor cable as shown
in the diagram.
3 Connect the Click 200 to the DIN rail.
4 Connect the ground terminal to the DIN rail and the
earth ground wire to the lug bolt on the bottom of the
pole-mount box.
5 Connect the exterior lug bolt to earth ground.
6 Connect 10–30 VDC to the +DC and –DC terminals on
the appropriate side of the Click 200.
Note. The Click 200 has one side marked PROTECTED and
one marked UNPROTECTED; which you use depends on
your installation. If you’re unsure which side to use, consult
the installation designs, Chapter 2 of the SmartSensor HD
User Guide, or Wavetronix Technical Services.
6
Attach the pole-mount cabinet
Note. If you have a 9-conductor cable, it will have the following wiring differences:
˽
There is a gray ground wire that can be plugged into any GND terminal.
˽
Instead of one drain, there are three; they can also be plugged into any GND terminals.
˽
The white +485 wire does not have a blue stripe.
-DC (Black)
+DC (Red)
+485 (White)
-485 (Blue)
CTS (Brown)
RTS (Orange)
Drain
TD (Yellow)
RD (Purple)