Instruction handbook – Watson-Marlow PD12I User Manual
Page 8

INSTRUCTION HANDBOOK
PD12I / PD12P
PD12IP IH 1.03 EN
Version: 1.03
Page 8 of 20
3.4
Addressing of filling station
Address
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
SW1 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0
SW2 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0
SW3 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0
SW4 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0
Fig. 3.3
Address "1" is the factory setting of PD12.
If the PD12 is one of several filling stations in a system, none of the stations may have the
same address and it must therefore be changed.
Change of address is performed via a dip-switch placed at the bottom of the PD12. This
change may only be carried out when the machine is turned off at the main power switch.
Addresses between 1 and 16 may be chosen, and Fig. 3.3 shows the various combinations.