OPERATOR’s MANUAL

FC32

FC32 OM 1.02 EN

Version: 1.02

Page 7 of 10

5.3 Changing the screw head

Fig. 5.3

Fig. 5.4



Pull the spring-loaded release sleeve down, and pull at the same time the screw head down. The
screw head will come off the quick change chuck.
For mounting the new screw head, press the head up in the quick change chuck. When the air supply
is re-opened the unit is ready for operation with the new screw head, after adjustment of the height as
described in section 5.1.

5.4 Change of bottle grip

The bottle grip can be released by unscrewing the finger screw fix the bottle grip to the arm. The new
bottle grip is mounted with the finger screw, and adjusted as described in section 5.1.