8 specifications – Watson-Marlow PD/40 User Manual
Page 18
![background image](https://www.manualsdir.com/files/809084/content/doc018.png)
18
8 SPECIFICATIONS
8.1
General information
Description
Value
Maximum allowable pressure in vessel
2300 kPa
334 psi
Maximum allowable working pressure
discharge line before pulsation damper
1600 kPa
232 psi
Allowable ambient temperature
−20 to +45
°
C
−4 to +113 °F
Allowable product temperature
−10 to +80 °C
+14 to +176 °F
Allowable storage temperature
−40 to +70
°
C
−40 to +158 °F
Maximum surface temperature
+90 °C (T5)
+194 °F (T5)
Air volume vessel
See: identification plate
8.2
Torque values
Component
Description
Unit
PD/40
PD/65
PD/100
Pressing ring (pos. 7)
Thread
M115 x 2
M145 x 2
M185 x 3
Torque value
N/A
N/A
N/A
Toolbar diameter mm
Ø16
Ø16
Ø16
inch
Ø0.63
Ø0.63
Ø0.63
Hose clamp (pos. 8)
Thread
M8
M8
M10
Torque value
1)
Nm
12 - 25
15 - 35
15 - 35
lbf in 106 - 220
133 - 310
133 - 310
Key width
mm
13
13
17
inch
0.51
0.51
0.67
Connecting flange (pos. 11) Thread
M8
M10
M12
Torque value
Nm
25
50
85
lbf in 220
440
750
Key width
mm
13
17
19
inch
0.51
0.67
0.75
1) Minimum torque value based on new clamps with smooth thread.
See also chapter 6.3 Replacing the pulsation damper hose point 17 for extra instruction on hose