19 Troubleshooting

Error

Cause

Remedy

Pump does not draw in

Direction of rotation not correct

Check direction of rotation

No wetting liquid in the pump

Fill pump with liquid

Screw fastening not tight

Check screw fastening

Suction pipe too long

Adapt suction pipe

Pipe cross-section too narrow

Adapt suction pipe

Shaft seal leaking

Check all seals for damage

Wear in the pump

Change wearing parts

Motor speed not correct

Measure, regulate speed

Scraper and cartridge wrongly
inserted

Check position (see changing
direction of rotation)

Pump does not deliver

Direction of rotation not correct

Check direction of rotation

Suction and pressure pipe
confused

Check pipe system

Motor speed not correct

Check speed based on output
diagrams

Wearing parts worn

Replace wearing parts

Scraper and cartridge wrong

Check position (see changing
direction of rotation)

Inserted closed gate valve

Check pipe system

Pump is noisy

Noises come from the drive

Consult WATSON-MARLOW

Noises come from the pump

Consult WATSON-MARLOW

Suction pipe too small (cavitation)

Shorten suction pipe or increase
diameter, reduce speed

Knocking noises from the pump
head

Gate valve wear

Noises from bearing block

Fill oil, change tapered roller
bearings

Coupling not aligned

Align coupling with hairline

Pump leaking at leakage
hole

Shaft seal leaking

Change GLRD or radial shaft
sealing rings

O-ring seal leaking

Replace O-ring

Radial shaft sealing ring on the
bearing block leaking, oil escapes

Dismantle bearing block,
replace radial shaft sealing rings

Pump leaking at the front
housing

Housing seal not or wrongly
installed

Install housing O-ring correctly or
replace

Housing seal defective

Install housing O-ring correctly or
replace