19 Troubleshooting

Error

Cause

Remedy

Direction of rotation not correct

Check direction of rotation

No wetting liquid in the pump

Fill pump with liquid

Screw fastening not tight

Check screw fastening

Suction pipe too long

Adapt suction pipe

Pipe cross-section too narrow

Adapt suction pipe

Seals leaking

Check all seals for damage

Wear in the pump

Change wearing parts

Pump does not draw in

Motor speed not correct

Measure, regulate speed

Direction of rotation not correct

Check direction of rotation

Suction pipe is leaking

Check pipe system

Motor speed not correct

Check speed based on output
diagrams

Wearing parts worn

Replace wearing parts

Pump does not deliver

Inserted closed gate valve

Check pipe system

Noises come from the drive / pump

Consult
Watson-Marlow MasoSine

Suction pipe too small (cavitation)

Shorten suction pipe or increase
diameter, reduce speed

Knocking noises from the pump head Scrapergate wear
Noises from bearing housing

Fill oil, change tapered roller
bearings

Pump is noisy

Coupling not aligned

Align coupling with hairline

Seal system leaking

Change Mechanical or Lip seal
system

O-ring seal leaking

Replace O-ring

Pump leaking at leakage
hole
Pump is noisy

Lip seals on the bearing block
leaking, oil escapes

Dismantle bearing block,
replace radial shaft sealing rings

Pump leaking at the front
housing

O-rings in the Liner not or wrongly
installed

Install housing O-ring correctly or
replace

Foreign body in the pump

Remove foreign body, examine
pump for damage

Power supply interrupted

Check electrical installations
(fuses, drive)

Pump has blocked

Defect on the drive

(Separate the coupling and turn
the pump by hand)

Strong wear after short
operating time

Solids in the pumped material

Pumped material is abrasive

Frequent change of the wearing
parts, change material pairing
Choose larger pump,
reduce speed

Rotor not tightened correctly on
installation

Tighten closing nut firmly on block

Rotor has wear on one
side

Adjusting dimensions changed after
working on the bearing housing

Check and correct the adjusting
dimensions

(see page 12)

Pump not clean after CIP
cleaning

Cleaning regulation not complied with Choke on the pressure side

Check differential pressure 3-4 bar

Rotor not correctly tightened

Tighten closing nut firmly on block

Rotor has seized on
stator

Temperature too high
(thermal expansion)

Choose Liner with larger
tolerances