OPERATORS MANUAL

Machine Type:

GD30P

GD30P OM 1.01 EN

Ver 1.01

Date 2006-10-24

Page 10 of 14

3. Acceleration/deceleration

Value: An integral number
Range: 1 - 100
The acceleration and the deceleration will always be the same. The lowest value (1) will
give the slowest acceleration, and the highest value (100) will give the fastest
acceleration.

If the acceleration is changed, a recalibration should be made.



4. Reversing (back suction)

Value: An integral number
Range: 0 - 10
If the pump is moved a little backwards (reversing) after the completion of fillings, a minor
back suction will be created. This can prevent dripping from the filling needle.
The value "0" will give no reversing, but the value "10" will give maximum reversing.

ALWAYS make a recalibration if the reversing value is altered.
For other programming possibilities, reference is made to the MC12 manual.