Verilink SNMP Management (No Part Number) Product Manual User Manual
Page 6

SNMP Management
SNMP-6
Verilink SNMP
NOTE: To determine the clock source for Verilink products, see the Verilink
enterprise MIBs.
Table 5 DS1 Near End Group 2
dsx1LoopbackConfig Access is read-write:
• dsx1NoLoop(1) if no loopback is in progress.
• dsx1PayloadLoop (2) if near-end Payload Loopback (PLB) is
enabled.
• dsx1LineLoop(3) if near-end Line Loopback (LLB) is enabled.
For “read”:
• dsx1OtherLoop(4) for loopbacks that are not defined in this
object.
For “read”:
• dsx1OtherLoop(4) if RLB is enabled.
dsx1LineStatus
dsx1NoAlarm(1) if no alarm present.
dsx1RcvFarEndLOF(2) if far-end LOF (Yellow Alarm).
dsx1RcvAIS(8) if far-end AIS.
dsx1LossOfFrame(32) if near-end LOF (Red Alarm).
dsx1LossOfSignal(64) if near-end LOS.
dsx1LoopbackState(128) if near end is looped.
dsx1OtherFailure(4096) if near-end BER exceeded.
dsx1RcvFarEndLOF and dsx1RcvAIS are supported
for AS2000 equipment.
dsx1SignalMode
Access is read only.
none(1) - indicates that no bits are reserved for
signaling on this channel.
dsx1TransmitClock
Source
Access is read-only.
loopTiming(1) if NET timing is selected.
localTiming(2) if internal (INT) timing is selected.
throughTiming(3) if THROUGH timing is selected.
dsx1Fd1
Access is read-only.
dsx1Ansi-T1-403(2) is always on.
dsx1Att-54016(4) is always on.
Object-Type
Parameters
Object-Type
Parameters
dsx1CurrentIndex
A number calculated with the formula in
dsx1CurrentSESs
The number of Severely Errored Seconds in the
current 15-minute interval.
dsx1CurrentSEFSs
The number of Severely Errored Framing Seconds in
the current 15-minute interval.
dsx1CurrentESs
The number of Errored Seconds in the current 15-
minute interval.
dsx1CurrentUASs
The number of Unavailable Seconds in the current
15-minute interval.
dsx1CurrentCSSs
0 (Not supported).
dsx1CurrentPCVs