beautypg.com

About advanced features & operation, Page 19, I2:00 – Venstar T1100FS User Manual

Page 20: I8:88

background image

About Advanced Features & Operation

HEAT/COOL DIFFERENTIAL - The Heat and Cool setpoints will not be
allowed to come any closer to each other than the value set in Advanced
Setup step #7, on page 13. This minimum difference is enforced during
Auto changeover and Program On operation.

Note: To increase the spread between the heating and cooling setpoints,
press the MODE button until only the heat setpoint is displayed; adjust to
the desired setpoint. Press the MODE button until only the cool setpoint
is displayed; adjust to the desired setpoint. Press the MODE button again
to enter the Auto-changeover mode where both the heat and cool
setpoints are displayed.


OFF

o

Pm

I2:00

Mo

88

88

H

EAT

C

OOL

ONOFF

AUTO

Fan On

Program

Service Filter

Locked

Outside

Setup

On

o

Am

Pm

I8:88

Day

Night

Evening

Morning

SuMoTuWeThFrSa

OFF

o

Pm

I2:00

Mo

MEMORY BACKUP - In the event of a power loss, the thermostat will retain
the stored program settings without external power or batteries.

PROGRAMMABLE FAN -
hour and the fan will run for the number of minutes selected in step #9 on
page 14. Steps 10 & 11 restrict the hours during which the programmable
fan may operate; step #10 is the start time and step #11 is the stop time.
Selecting the same start and stop times will cause the fan to operate 24
hours a day.

This timer will start the fan at the top of each

Page 19

WARNING: This will reset all Time Period and Advanced Programming to
the default settings. Any information entered prior to this reset will be
permanently lost.

FACTORY DEFAULTS -
settings back to the factory default settings, follow the instructions below.

If, for any reason, you desire to return all the stored

Place the therm-
ostat in the OFF
mode.

Press
MODE button.
While holding the
MODE button, press
and hold the DOWN
button for 5 sec-
onds. All icons will
appear on the display.

and hold the

After all of the icons
appear, release the
MODE and DOWN
buttons. Then press
and hold the FAN
button for 5 seconds.

After the letters Fd
appear on the display
(Factory Default),
release the FAN
button. Press the
MODE button twice
to return to normal
operation.

MODE

MODE

MODE

FAN