Venstar T1100FS User Manual
Page 14
![background image](https://www.manualsdir.com/files/808469/content/doc014.png)
Press
Press
Press
Press
Press
Continued
MODE
MODE
MODE
MODE
MODE
0
4
Setup
Eh
5
OFF
Setup
2
6
Setup
2
7
C
OOL
H
EAT
Setup
6
8
Cy
Setup
Advanced Setup
Select the reversing valve
polarity for Heat Pump
operation:
O = Energize in cooling
b = Energize in heating
(Step 4 only appears if
heat pump is on in step 3)
b
O
Page 13
Select Electric Heat operation:
On = 1st stage electric heat
Off = 1st stage gas heat
On
Off
(Step 5 only appears if
heat pump is off in step 3)
Adjust the deadband
for the 1st stage.
(1 - 6 )
Adjust the minimum
difference between
cooling & heating
setpoints.
(0 - 6 )
(d1, d, 2 - 6)
Select the cycles per
hour limit:
d=cycles per hour
limit defeated
d1=d + defeat 5 min.
compressor lockout