About advanced features & operation, Page 17, I2:00 – Venstar T1000FS User Manual
Page 18: I8:88
About Advanced Features & Operation
HEAT/COOL DIFFERENTIAL - The Heat and Cool setpoints will not be
allowed to come any closer to each other than the value set in Advanced
Setup step #8, on page 12. This minimum difference is enforced during
Auto changeover and Program On operation.
Note: To increase the spread between the heating and cooling setpoints,
press the MODE button until only the heat setpoint is displayed; adjust to
the desired setpoint. Press the MODE button until only the cool setpoint
is displayed; adjust to the desired setpoint. Press the MODE button again
to enter the Auto-changeover mode where both the heat and cool
setpoints are displayed.
OFF
o
Pm
I2:00
88
88
H
EAT
C
OOL
ONOFF
AUTO
Fan On
Program
Locked
Setup
On
o
Am
Pm
I8:88
Day
Night
Evening
Morning
OFF
o
Pm
I2:00
MEMORY BACKUP - In the event of a power loss, the thermostat will retain
the stored program settings without external power or batteries.
SINGLE SETPOINT BEHAVIOR - When configured as a Single Setpoint
thermostat, page 11, step 3, the large number is the setpoint. In Auto
mode the deadband is above and below the setpoint. To avoid short
cycling in single setpoint it is recommended that the deadband be set
for at least 2 degrees, page 12, step 7.
Page 17
WARNING: This will reset all Time Period and Advanced Programming to
the default settings. Any information entered prior to this reset will be
permanently lost.
FACTORY DEFAULTS -
settings back to the factory default settings, follow the instructions below.
If, for any reason, you desire to return all the stored
Place the therm-
ostat in the OFF
mode.
Press
MODE button.
While holding the
MODE button, press
and hold the DOWN
button for 5 sec-
onds. All icons will
appear on the display.
and hold the
After all of the icons
appear, release the
MODE and DOWN
buttons. Then press
and hold the FAN
button for 5 seconds.
After the letters Fd
appear on the display
(Factory Default),
release the FAN
button. Press the
MODE button twice
to return to normal
operation.
MODE
MODE
MODE
FAN