16

103426

UNVENTED NATURAL GAS LOG HEATER

INSPECTING
BURNERS

Check pilot flame pattern and burner flame
patterns often.

PILOT FLAME PATTERN

Figure 30 shows a correct pilot flame pat-
tern. Figure 31 shows an incorrect pilot
flame pattern. The incorrect pilot flame is
not touching the thermocouple. This will
cause the thermocouple to cool. When the
thermocouple cools, the heater will shut
down.

Thermocouple

Pilot Burner

Figure 30 - Correct Pilot Flame Pattern

Pilot Burner

Thermocouple

Figure 31 - Incorrect Pilot Flame Pattern

If pilot flame pattern is incorrect, as shown
in Figure 31

• turn heater off (see To Turn Off Gas

to Appliance, page 15 [thermostat-
controlled models] or page 16
[manually-controlled models])

• see Troubleshooting, pages 18

through 20

TO TURN OFF GAS

TO APPLIANCE

8.

Push in and turn control knob coun-
terclockwise to the HIGH position.
Both burners should light. Set con-
trol knob to desired setting.

WARNING: Do not operate

heater between locked positions.

CAUTION: Do not try to ad-

just heating levels by using the
manual shutoff valve.

Figure 29 - Pilot

The variable control valve can be set to
any heat setting and flame height desired,
by simply turning the control knob until
that setting is attained. Even the lowest
setting provides realistic flames and glow-
ing embers from two burners. Selecting
higher settings produces greater heat
output. This results in increased heating
comfort.

7.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.
• If control knob does not pop out

when released, contact a qualified
service person or gas supplier for
repairs.

Note:

If pilot goes out, repeat steps

3 through 7.

Shutting Off Heater

1.

Press in and turn control knob clock-
wise

Clockwise

to the HIGH position.

2.

Turn the control knob clockwise

Clockwise

to the PILOT position.

3.

Press in control knob and turn clock-
wise

Clockwise

to the OFF Position.

Shutting Off Burners Only (pilot
stays lit)

1.

Turn the control knob clockwise

Clockwise

to the HIGH position.

2.

Press in and turn control knob clock-
wise

Clockwise

to the pilot position.

Thermocouple

Ignitor Electrode

Pilot Burner

OPERATING
HEATER

Manually-Controlled Models

Continued

4.

Wait five (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow “B” in the safety in-
formation above. If you don’t smell
gas, go to the next step.

5.

Press in control knob and turn coun-
terclockwise

Clockwise

to the PILOT po-

sition. Keep control knob pressed in for
five (5) seconds (see Figure 28, page 15).

Note:

You may be running this

heater for the first time after hook-
ing up to gas supply. If so, the con-
trol knob may need to be pressed in
for 30 seconds. This will allow air to
bleed from the gas system.

6.

With control knob pressed in, press
and release ignitor button. This will
light pilot. The pilot is attached to the
front burner. If needed, keep press-
ing ignitor button until pilot lights.

Note:

If pilot does not light, contact

a qualified service person or gas sup-
plier for repairs. Until repairs are
made, light pilot with match. To light
pilot with match, see Manual Light-
ing Procedure
, column 2.

VARIABLE CONTROL

OPERATION

MANUAL LIGHTING

PROCEDURE

1.

Follow steps 1 through 5 under Light-
ing Instructions
, page 15.

2.

Depress control knob and light pilot
with match.

3.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Now
follow step 8, above.

Continued