MAINTENANCE

Do not operate the Air Caddy Assembly unit until you have read the ‘Operator’s
Manual’.

When the bowl becomes dirty, replace the bowl or wipe with a clean dry cloth.

Depressurize the unit before removing either bowl.

FILTER/REGULATOR MAINTENANCE

Each filter unit must be operated with a filter element.

Periodically clean the filter element by removing the filter by tapping on the surface;
blow off debris with an air blowgun.

Change filter when pressure drop exceeds 10 psig or every 12 months.

To Remove the Filter Element

Turn the air pressure off and vent the air from the air caddy system.