beautypg.com

Inspecting burner – Desa WMN10 User Manual

Page 16

background image

www.desatech.com

123995-01C

16

1/2 GLASS HEIGHT

CORRECT FLAME PATTERN

AT HIGH POSITION

INCORRECT FLAME PATTERN

AT HIGH POSITION

1/2 GLASS HEIGHT

1/2 GLASS HEIGHT

CORRECT FLAME PATTERN

AT HIGH POSITION

INCORRECT FLAME PATTERN

AT HIGH POSITION

1/2 GLASS HEIGHT

Figure 23 - Correct Burner Flame Pattern

Yellow
Tipping

Figure 24 - Incorrect Burner Flame

Pattern

BURNER FLAME PATTERN
INFRARED MODELS

Figure 25 shows a correct burner flame pat-
tern. Figure 26 shows an incorrect burner
flame pattern.
If burner flame pattern is incorrect, as shown
in Figure 26
• turn heater off (see To Turn Off Gas to Ap-

pliance, page 14)

• see Cleaning, page 17

Figure 26 - Incorrect Burner Flame

Pattern (Dual Burner Shown)

Figure 25 - Correct Burner Flame Pattern

(Dual Burner Shown)

INSPECTING BURNER

Continued

WARNING: If yellow tipping

occurs, your heater could pro-

duce increased levels of carbon

monoxide. If burner flame pattern

shows yellow tipping, proceed

with the following instructions.

NOTICE: Do not mistake orange

flames with yellow tipping. Dust

or other fine particles enter the

heater and burn causing brief

patches of orange flame.

BURNER FLAME PATTERN BLUE
FLAME MODELS

Figure 23 shows a correct burner flame pat-
tern. Figure 24 shows an incorrect burner
flame pattern. The incorrect burner flame
pattern shows yellow tipping of the flame.
It also shows the flame higher than 1/2 the
glass panel height.
If burner flame pattern is incorrect, as shown
in Figure 24
• turn heater off (see To Turn Off Gas to Ap-

pliance, page 14)

• see Cleaning, page 17

(Models GWN6 and GWP6 will be lower due to

lower input rating)

This manual is related to the following products: