Operation – Desa WMN10 User Manual

Page 14

background image

www.desatech.com

123995-01C

14

8. Keep control knob pressed in for 30 sec-

onds after lighting pilot. After 30 seconds,
release control knob.
• If control knob does not pop up when

released, contact a qualified service
person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 4 thru
7. Wait one (1) minute before lighting pilot
again.

9. Turn control knob counterclockwise

to desired heating level. The main

burner should light. Manual control heat-
ers should be used in locked positions.

10. To leave pilot lit and shut off burners only,

turn control knob clockwise

to the

PILOT position.

WARNING: Always operate

manual control heaters at the

locked positions. Operation

between these positions may

create a possible health hazard

if used in a poorly ventilated

room. Read owner’s manual for

complete instructions.

OPERATION

Continued

OFF

Figure 17 - Control Knob In The OFF

Position (Manual Control Models)

Ignitor Button

Control Knob

Figure 19 - Pilot (pilot may vary from

illustration)

Figure 18 - Control Knob In The OFF

Position (Thermostat Models)

Ignitor Button

Control Knob

O

OT

CAUTION: Do not try to ad-

just heating levels by using the

equipment shutoff valve.

TO TURN OFF GAS

TO APPLIANCE

1. Turn control knob clockwise

to the

OFF position.

2. Turn off any electric power to the appli-

ance if service is to be performed.

3. Close equipment shutoff valve (see Figure

14, page 12.

MANUAL LIGHTING

PROCEDURE

1. Remove front panel (see page 10).
2. Follow steps 1 through 7 under Lighting

Instructions, page 13.

3. With control knob pressed in, strike match.

Hold match to pilot until pilot lights.

4. Keep control knob pressed in for 30 sec-

onds after lighting pilot. After 30 seconds,
release control knob. Now follow step 9,
under Lighting Instructions, column 2.

5. Replace front panel.

THERMOSTAT

CONTROL OPERATION

Thermostat models only
The thermostatic control used on these models
differs from standard thermostats. Standard
thermostats simply turn on and off the burner.
The thermostat used on this heater senses
the room temperature. At times the room may
exceed the set temperature. If so, the burner
will shut off. The burner will cycle back on when
room temperature drops below the set temper-
ature. The control knob can be set to any heat
level between 1 and 5. This adjusts the amount
of gas flow to the burner. This increases or
decreases the burner flame height.
Note: The thermostat sensing bulb mea-
sures the temperature of air near the heater
cabinet. This may not always agree with
room temperature (depending on housing
construction, installation location, room size,
open air temperatures, etc.). Frequent use of
your heater will let you determine your own
comfort levels.