Pca-com, Power connection for flx-bc with braid only, 76mm (3”) braid – Thermon PCA-COM User Manual
Page 5: Tape provided separately ul label, Cut and remove primary insulation jacket, Skive outside of black matrix

4
PCA-COM
3.3.
Feed cable and ground lead through
expediter base as shown. Feed cable
and ground lead through grommet (above
the crimp).
3.2.
Trim braid to approximately 76mm (3”).
Crimp 12/10 AWG compression lug to
ground braid and ground lead.
3.1.
Separate braid strands at edge
of overjacket and pull cable through
opening.
Ground Lead
Wire
12/10 AWG
Crimp
Expediter
Base
Grommet
Ground
Lead
8AWG Crimp
Cable
152mm
(6”)
Power connection for FLX-BC with braid only.
76mm
(3”)
Braid
3.4.
Slide expediter toward pipe and route
cable through base, grommet, and NPT
threaded cap. Secure cap to base with the
captive screws.
3.5.
Mount expediter to pipe using two (2)
circumferential bands of 19mm (3/4”)
wide tape.
3.6.
Place UL® label provided as shown,
locate on opposite side from rectangular
side opening.
Pip
e H
ea
tin
g C
ab
le 1
34
N
HS
X
®
or
FL
X™
H
ea
tin
g C
ab
le S
ys
tem
Ins
tall
C
ab
le p
er N
EC
A
rti
cle
42
7
Th
erm
on
M
an
ufactu
rin
g C
o.
10
0
Th
erm
on
D
r., San Marco
s,
Te
xas 7866
6
1-8
00
-7
30
-4
32
8
P
N
2
74
00
Tape Provided
Separately
UL Label
3.7.
Cut and remove primary insulation jacket.
3.8.
Skive outside of black matrix.
3.9.
Cut V-Notch in matrix and pull bus wires
from matrix. Cut and remove center
matrix.
Do not cut bus wire strands.
117mm
(4-5/8”)
Bus Wire
Primary Insulation
Ground Lead
Matrix
Ground Lead
Ground Lead
Ground Lead
Black Matrix