SECTION 5 SPECIFICATIONS
ELECTRICAL:
Supply Voltage: 120 AC Single Phase
Ambient Temperature:
0°C to +40°C
Fuses:
2 x 1 A 20mm Quick Blow
Relay Outputs:
Pump Relay: 3A single pole
Aux. Relay: 3A single pole changeover
MECHANICAL:
Dimensions:
SMT 100 Unit:
Width: 165mm
Height: 100mm
Depth: 85mm
Sensor:
diameter: 7.3mm (8.5mm
for heat shrink)
Weight:
SMT 100 Unit:
0.96Kg
Box Material:
Plastic
SENSORS:
Type:
SX
TM
PT 100 Platinum Film
Compensation:
3 wire compensated
PARTS LIST
SMT 100 Unit
C0132
SX PT100 Sensor Assembly: 25m Collector
A0741
SX PT100 Sensor Assembly: 10m Collector
A7143
SX PT100 Sensor Assembly: 5m Tank
A0742
SX PT100 Sensor Assembly: 5m Return
A7141
SX PT100 Sensor Assembly: 0.5m Return
A0740
SX Sensor Extender 10m
A6911
SX Sensor Extender 20m
A6921
SX Sensor Extender 50m
A6951
External relay 16A
C0328
CE
This product has been tested to the EU EMC 89/336/EEC directive according to the
Manufacturers report, which is available upon request.
This product is in conformance with the Low Voltage Directive 73/23/EEC.
Thermomax certifies that this datalogging and / or control device has been
manufactured to an ISO 9002 Quality System.
Thermomax undertakes to repair or replace the device, if same is shown to be
defective in its manufacture and / or components, but Thermomax shall not be
responsible for any other financial or economic loss (or any indirect loss) which may
be incurred by the buyer / customer or others in the use of the device.
Any claim for repair or replacement must be made not later than 15 months after the
date of manufacture.
15