SECTION 3 SMT 100 OPERATION
In order to understand the operation of the SMT 100 this section should be read
carefully.
3.1
DESCRIPTION
DISPLAY SELECT
TEMPERATURE
INDICATORS
DISPLAY
DISPLAY TEMPERATURE SET
FROST
PUMP STATE
SELECT INCREASE / DECREASE PROTECTION
INDICATOR
KEY
SWITCHES
TEMPERATURE
ADJUST KEY
(HIDDEN)
3.1.1 DISPLAY SELECT INDICATORS:
(WITH SELECT INDICATOR FLASHING)
KEYPAD LOCK ENABLED KEYPAD LOCK DISABLED
(DISPLAY MODE)
(PROGRAMMING MODE)
:
Collector temperature display
Minimum collector temp. set point (TC)
:
Tank temperature display
Tank or Auxiliary set point (TT)
:
Actual Delta T temperature
Delta T temperature set.