Tecfluid APTM44 User Manual
Page 4
![background image](https://www.manualsdir.com/files/807422/content/doc004.png)
Cod.:E-MI-2152004I / Rev.: 1
4
5
WORKING
The APTM44 needs no adjusting to adapt to the pick-up or control instrument.
In the event that there are pulse outputs with no flow in the turbine, what is most probable is that
the cables to the pick-up are too long or that they are too near mains cables.
7
TECHNICAL CHARACTERISTICS
8.1
Environment
The plastic case has protection as per IP 40 and the terminals as per IP 20.
The working temperature limits are 0 to 50
o
C
8.3
Mains supply
The standard mains voltage is 220 Vac 50/60 Hz. AC Mains voltages of 240 V, 110 V y
24 V 50/60 Hz. and 24 Vdc supply voltage are available on order.
The power consumption is less than 1 W.
The instrument is not supplied with a mains filter and in the exceptional cases that, due to high
levels of mains interference, a mains filter is needed, this must be installed externally. Due to the low
power consumption, almost any small mains filter will be adequate.
8.5
Pulse Output
The output pulse has a pulse width of 1 ms.
The TTL outputs are directly from a CMOS integrated circuit and have a load current of 1 mA
maximum.
8.7
Pulse Input
The input is intended for an inductive pick-up coil.
The maximum input frequency is about 1500 Hz.