Cod.:E-MI-2152004I / Rev.: 1

2

1

WORKING PRINCIPLE


The amplifier for the TM-44 is designed to avoid problems of electrical interferences in

installations where the turbine is located at a big distance from the electronic control equipment.

The turbine pick-up generates very low level pulses (in the mV range). Given that the instrument

input must detect these low level pulses, it is very susceptible to electrical interferences, especially to
mains interferences. The probability of being affected by interferences increases with the length of the
cable between the pick-up and the instrument.

The APTM44 amplifier converts the pulses from the turbine pick-up into two TTL level signals

which are out of phase. This output signal is compatible with the pick-up input circuit of Tecfluid
instruments and it appreciably increases the rejection of interferences which can be picked up by a long
cable.

2.1 Limitations


The maximum frequency should be less than 1500 Hz.



2.3

Applications


a). The elimination of interferences in long cables between the turbine and the control

instrument.

b). Signal conditioning for instruments not provided with a pick-up input. One of the TTL outputs

can be used as an input for an industrial robot etc.

c). For connecting two or more pick-up input instruments to the same turbine.


3

INSTALLATION


The APTM44 is housed in an IP40 plastic case for mounting inside an electrical control panel.

The case has a clip for mounting on DIN 46 277 or DIN EN 50 022 rails.