beautypg.com

Technical characteristics, 7 technical characteristics – Tecfluid LP Series User Manual

Page 8

background image

8

7 TECHNICAL

CHARACTERISTICS

Accuracy

± 5 mm of the measured value

Scale length

~100 mm

Scale

% or height

Liquid density

0,6 ... 2 kg/l

Measuring range

300 mm to 6 m

Fluid temperature

-60ºC ... 150ºC
on request -120ºC ... 400ºC with thermal separator

Ambient temperature:

-10ºC ... 80ºC

Working pressure

PN40 (others on request)

Installation

Vertically, on top of the tank or side mounted by means of external chamber

Connections

EN 1092-1 DN40 flange
Thread connections G1½ or 1½” NPT
sanitary connections according to ISO 2852, SMS 1145, DIN 11851, TRI-CLAMP®
(Other connections on request)

Optional limit switches in the indicator housing:

LP-AMM

1 o 2 SPDT micro-switches with potential free contacts

Maximum current:

3A.

Maximum voltage:

250 VAC.

LP-AMD

1 o 2 slot inductive sensors, according to EN60947–5-6 standard (NAMUR)

Power supply: 8.2 VDC

Optional transmitters:

TH7 … TH7H

2-wire transmitter with 4-20 mA analog output

Power supply: 12 to 36 VDC
HART protocol with model TH7H

TH5 Ex … TH5H Ex

2-wire transmitter with 4-20 mA analog output
Certified Ex ia IIC T4 or T6 (ATEX)
Power supply: 12 to 30 VDC
HART Protocol with model TH5H Ex