Pumps should be mounted upstream from 
the sensor to avoid the suction part of the 
pump (vacuum) that could damage the 
sensor liner (see the table on page 8). 
If there is a point where the difference in level 
is greater than 5 m an air inlet valve should 
be installed after the sensor to avoid a 
vacuum effect that could damage the sensor 
liner (see the table on page 8). 
Control valves or stop cocks should 
always be installed downstream from the 
sensor to assure that the pipe is always 
full of liquid. 
Reduction of the DN
In installations where, for reasons of the 
flow rate to be measured, a sensor of a 
smaller DN than the pipe DN must be 
mounted, the reduction must be done with 
an angle smaller than 4º to avoid 
turbulences that can give false readings. 
If the reduction angle is greater then the 
straight pipe sections indicated on the 
previous page must be respected. 
α
α < 4º
α > 4º
α