Tecfluid FLOMID Series User Manual
Page 3

3
Mixtures 
If liquids of different conductivities are mixed it is 
necessary to install the sensor a minimum of 30 DN 
from the point of mixture in order to obtain a uniform 
conductivity of the liquid and stabilize the readings. 
If this distance is less, the readings may be unstable. 
INSTALLATION
This should be made in a point that guarantees that the pipe is always completely full.
Avoid high points of the pipes where air pockets usually form, or pipes with falling flow where
vacuums can form.
Partially full pipes can produce important reading errors.
Straight pipe sections 
Are necessary before and after the 
sensor. The minimum distances are 
the following: 
 Upstream : 5 DN 
Downstream : 3 DN
In installations with turbulent flow it 
may be necessary to increase these 
distances. 
Sensor position 
The most adequate position is 
with the electrodes in a 
horizontal plane. In this way, 
deposits of particles on the 
electrodes are avoided. 
Flow rate measurement
with open discharge 
makes it necessary to 
install the flowmeter in a 
pipe section with a siphon 
which avoids stagnation of 
air in the sensor. 