OPERATION

Flow rate variations displace the float in the metering tube and as it passes by the point where the
60 AMD... limit switch is, by means of magnetic coupling acts on the detectors vane changing its
position from one detection position to the other.

The vane position is maintained until the float passes in the opposite direction at the limit switch
position, changing the inductive detector to its original state.

DIMENSIONS

DN

A

15-20

90 mm

20-25

96 mm

40

111 mm

50

117 mm

65-80

130 mm

ELECTRICAL CONNECTION

For the electrical installation it is recommended to use multiple conductor cables with individual
cable sections in the order of 0.25 or 0.5 mm

2

in order to make it easier to connect. Individual

cables should not be used as they will impair the IP-65 rating of the cable gland.

Before starting the installation, check that the cable to be used are the right size for the cable
gland on the connector, this will guarantee the instrument will stay water tight.

Peel the outside insulation to free the inner cables. It is recommended to tin the cables at the
ends of the wires to avoid loose ends which can produce short circuits. Pass the cables through
the cable gland and screw in the cables in their positions. Once the wiring is finished make sure
that the cables are well gripped by the cable gland to maintain the ingress protection degree.

This manual is related to the following products: